... | ... | @@ -9,8 +9,18 @@ |
|
|
* Sameer's prototype code [sameer_prototype_chem.py](https://gitlab.com/pdbe/ccd_utils/blob/master/sameer_prototype_chem.py) has procedure for setting chirality from the chem_comp_atom.pdbx_stereo_config value
|
|
|
|
|
|
* *27 May 2017*:
|
|
|
* Try the procedure from [sameer_prototype_chem.py](https://gitlab.com/pdbe/ccd_utils/blob/master/sameer_prototype_chem.py)
|
|
|
* Try the procedure from [sameer_prototype_chem.py](https://gitlab.com/pdbe/ccd_utils/blob/master/sameer_prototype_chem.py) results:
|
|
|
* commit [d4cd4046](https://gitlab.com/pdbe/ccd_utils/commit/d4cd40468c2fc999be8a92bd4fc095f5b27491bb) "Adapt procedure from sameer_prototype_chem.py to set the chirality of the rdkit atoms."
|
|
|
* failure [commit message](https://gitlab.com/pdbe/ccd_utils/commit/d4cd40468c2fc999be8a92bd4fc095f5b27491bb) includes details.
|
|
|
* the change sorts the inchikey match for GLU and SAC but GLC MAN remain problematic with end of inchikey not matching. GLU and SAC are simple with one chiral centre.
|
|
|
* likely reason is that the pdbx_stereo_config is based on a different atom order from rdkit.
|
|
|
* Could try to understand pdbx_chirality or randomly iterate through chiral centres flipping until chiral centres match but neither is a good idea! Instead:
|
|
|
## Try using assignChiralTypesFrom3D
|
|
|
* https://sourceforge.net/p/rdkit/mailman/message/35774134/ has Greg Landrum's suggestion:
|
|
|
* sanitizeMol
|
|
|
* Kekulize(mol);
|
|
|
* assignChiralTypesFrom3D(mol);
|
|
|
* assignStereochemistry(mol,true,true)
|
|
|
* compute2DCoords(mol)
|
|
|
* this should also get rid of `WARNING: Omitted undefined stereo` message as RDKit would do its own stereo centre assignment.
|
|
|
* will need ideal coordinates for this. |
|
|